Electrotechnics N4: Power in a balanced three-phase star load

Single-phase and three-phase circuits · 5 marks · free worked example

Share with your class:WhatsAppFacebookX

Question

A balanced star-connected load is supplied from a 400 V three-phase supply. The line current is 10 A and the power factor is 0.8 lagging. Calculate the phase voltage and the total power.

Given

  • VL=400 VV_L = 400\ \text{V}
  • IL=10 AI_L = 10\ \text{A}
  • cos⁡ϕ=0.8\cos\phi = 0.8

Solution, step by step

Phase voltage (star connection):

Vph=VL3=4003=230.94 V\begin{aligned} V_{ph} &= \frac{V_L}{\sqrt{3}} \\ &= \frac{400}{\sqrt{3}} \\ &= 230.94\ \text{V} \end{aligned}

Total power:

P=3 VLILcos⁡ϕ=3×400×10×0.8=5 542.56 W=5.54 kW\begin{aligned} P &= \sqrt{3}\, V_L I_L \cos\phi \\ &= \sqrt{3} \times 400 \times 10 \times 0.8 \\ &= 5\,542.56\ \text{W} \\ &= 5.54\ \text{kW} \end{aligned}

Answer: phase voltage 230.94 V, total power 5.54 kW.

Mistakes to avoid

  • In star, the line current equals the phase current and the line voltage is √3 times the phase voltage.
  • In delta it is the other way round: the voltages are equal and the line current is √3 times the phase current.